Parameter List
11
11.13 o: Keypad-Related Settings
YASKAWA SIEPC71061753C GA500 Technical Manual 437
No.
(Hex.)
Name Description
Default
(Range)
Ref.
o1-48
(11C8)
RUN
Trend Plot 1 Scale
Maximum Value
Sets the maximum value for the vertical axis used to display the monitor that was set in
o1-24 [Custom Monitor 1] as a trend plot. This parameter is only available with an LCD
keypad.
100.0%
(-299.9 - +300.0%)
763
o1-49
(11C9)
RUN
Trend Plot 2 Scale
Minimum Value
Sets the horizontal axis minimum value used to display the monitor set in o1-25
[Custom Monitor 2] as a trend plot. This parameter is only available with an LCD
keypad.
-100.0%
(-300.0 - +299.9%)
763
o1-50
(11CA)
RUN
Trend Plot 2 Scale
Maximum Value
Sets the maximum value for the vertical axis used to display the monitor that was set in
o1-25 [Custom Monitor 2] as a trend plot. This parameter is only available with an LCD
keypad.
100.0%
(-299.9 - +300.0%)
763
o1-51
(11CB)
RUN
Trend Plot Time Scale
Setting
Sets the time scale (horizontal axis) to display the trend plot. When you change this
setting, the drive automatically adjusts the data sampling time. This parameter is only
available with an LCD keypad.
300 s
(1 - 3600 s)
763
o1-55
(11EE)
RUN
Analog Gauge Area
Selection
Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog
gauge. This parameter is only available with an LCD keypad.
0 : +/- Area ( - o1-56 o1-56 )
1 : + Area ( 0 ~ o1-56 )
1
( 0, 1 )
763
o1-56
(11EF)
RUN
Analog Gauge Area
Setting
Sets the value used to display the monitor set in o1-24 [Custom Monitor 1] as an analog
meter. This parameter is only available with an LCD keypad.
100.0%
(0.0 - 100.0%)
763
o1-58
(3125)
Motor Power Unit
Selection
Sets the setting unit for parameters that set the motor rated power.
0 : kW
1 : HP
0
(0, 1)
763
o2: Keypad Operation
No.
(Hex.)
Name Description
Default
(Range)
Ref.
o2-01
(0505)
LO/RE Key Function
Selection
Sets the function that lets you use to switch between LOCAL and REMOTE
Modes.
0 : Disabled
1 : Enabled
1
(0, 1)
764
o2-02
(0506)
STOP Key Function
Selection
Sets the function to use on the keypad to stop the drive when the Run
command source for the drive is REMOTE (external) and not assigned to the keypad.
0 : Disabled
1 : Enabled
1
(0, 1)
764
o2-03
(0507)
User Parameter Default
Value
Sets the function to keep the settings of changed parameters as user parameter defaults
to use during initialization.
0 : No change
1 : Set defaults
2 : Clear all
0
(0 - 2)
765
o2-04
(0508)
Drive Model (KVA)
Selection
Sets the Drive Model code. Set this parameter after replacing the control board.
Determined by the drive
(-)
765
o2-05
(0509)
Home Mode Freq Ref
Entry Mode
Sets the function that makes it necessary to push to use the keypad to change the
frequency reference value while in Drive Mode.
0 : ENTER Key Required
1 : Immediate / MOP-style
0
(0, 1)
766
o2-06
(050A)
Keypad Disconnect
Detection
Sets the function that stops the drive if you disconnect the keypad connection cable
from the drive or if you damage the cable while the keypad is the Run command source.
0 : Disabled
1 : Enabled
0
(0, 1)
766
o2-07
(0527)
Keypad RUN Direction
@ Power-up
Sets the direction of motor rotation when the drive is energized and the keypad is the
Run command source.
0 : Forward
1 : Reverse
0
(0, 1)
766
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA CIPR-GA50C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CIPR-GA50C series and is the answer not in the manual?

YASKAWA CIPR-GA50C series Specifications

General IconGeneral
BrandYASKAWA
ModelCIPR-GA50C series
CategoryController
LanguageEnglish

Related product manuals