12.2 A: Initialization Parameters
500 YASKAWA SIEPC71061753C GA500 Technical Manual
Set H1-xx = 9F [MFDI Function Select = DWEZ Disable]. Deactivate the digital input to enable programs made
with DriveWorksEZ. Activate the terminal to disable the programs.
If A1-07 = 1 [DriveWorksEZ Function Selection = DWEZ Enabled], the drive will continue to disable DWEZ
when these conditions are true:
• Drive is not in operation
• The MFDI terminals set for H1-xx = 9F activate.
■ A1-11: Firmware Update Lock
No.
(Hex.)
Name Description
Default
(Range)
A1-11
(111D)
Expert
Firmware Update Lock
Protects the drive firmware. When you enable the protection, you cannot update the drive
firmware.
0
(0, 1)
0 : Disabled
Lock is disabled.
1 : Enabled
Lock is enabled.
■ A1-12: Bluetooth ID
No.
(Hex.)
Name Description
Default
(Range)
A1-12
(1564)
Bluetooth ID
Sets the password necessary to use Bluetooth to control the drive with a smartphone or tablet.
-
(0000 - 9999)
◆ A2: User Parameters
You can register frequently used parameters and recently changed parameters here to access them quickly. Use
Setup Mode to show the saved parameters.
■ A2-01 to A2-32: User Parameters 1 to 32
No.
(Hex.)
Name Description
Default
(Range)
A2-01 to A2-32
(0106 - 0125)
User Parameters 1 to 32
You can select a maximum of 32 parameters for the drive and save the values to parameters A2-01
to A2-32. Use Setup Mode to show the saved parameters. You can immediately access these saved
parameters.
Parameters in General-
Purpose Setup Mode
(Determined by A1-06)
Note:
• When the A1-06 [Application Preset] value changes, the settings for A2-01 to A2-32 change.
• You must set A1-01 = 1 [Access Level Selection = User Parameters] to access parameters A2-01 to A2-32.
• When A1-07 = 1 or 2 [DriveWorksEZ Function Selection = DWEZ Enabled or Enabled/Disabled wDigital Input], the drive saves qx-
xx [DriveWorksEZ Parameters] to A2-01 to A2-32.
The drive saves these parameters to A2-01 to A2-32.
• The drive saves a maximum of 32 parameters.
Note:
Set A1-01 = 2 [Advanced Level] or A1-01 = 3 [Expert Level] to save the necessary parameters.
• The drive automatically saves changed parameters to A2-17 to A2-32.
Note:
Set A2-33 = 1 [User Parameter Auto Selection = Enabled].
■ A2-33: User Parameter Auto Selection
No.
(Hex.)
Name Description
Default
(Range)
A2-33
(0126)
User Parameter Auto
Selection
Sets the automatic save feature for changes to parameters A2-17 to A2-32 [User Parameters 17 to
32].
Determined by A1-06
(0, 1)
0 : Disabled: Manual Entry Required