176 Program features
ST1 ST2 ST3 ST4 Additional
information
Par. Setting Par. Setting Par. Setting Par. Setting
8420 ST1 REF
SEL
50% 8430 65% 8440 60% 8450 35% State
reference
8421 ST1
COMMANDS
START
FRW
8431 START
FRW
8441 START
FRW
8451 START
FRW
Run, direction
and stop
commands
8422 ST1
RAMP
-0.2
(ramp
pair 2)
8432 1.5 s 8442 0 s 8452 1.5 s Acceleration/
deceleration
ramp time
8423 ST1 OUT
CONTROL
R=0,D=0
,AO=0
8433 AO=0 8443 AO=0 8453 AO=0 Relay, digital
and analog
output control
8424 ST1
CHANGE DLY
0 s 8434 2 s 8444 0.2 s 8454 2 s State change
delay
8425 ST1
TRIG TO ST 2
ENTER
SETPNT
8435 ENTER
SETPNT
8445 ENTER
SETPNT
8455 ENTER
SETPNT
State change
trigger
8426 ST1
TRIG TO ST N
NOT SEL 8436 CHANG
E DLY
8446 CHANG
E DLY
8456 CHANG
E DLY
8427 ST1
STATE N
STATE 1 8437 STATE 8 8447 STATE 8 8457 STATE 8
ST5 ST6 ST7 ST8 Additional
information
Par. Setting Par. Setting Par. Setting Par. Setting
8460 ST5 REF
SEL
40% 8470 65% 8480 0% 8490 0% State
reference
8461 ST5
COMMANDS
START
FRW
8471 START
FRW
8481 DRIVE
STOP
8491 DRIVE
STOP
Run, direction
and stop
commands
8462 ST5
RAMP
0s 8472 1.5 s 8482 -0.1
(ramp
pair 1)
8492 -0.1
(ramp
pair 1)
Acceleration/
deceleration
ramp time
8463 ST5 OUT
CONTROL
AO=0 8473 AO=0 8483 DO=1 8493 RO=1 Relay, digital
and analog
output control

Table of Contents

Other manuals for ABB ACS355 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS355 series and is the answer not in the manual?

ABB ACS355 series Specifications

General IconGeneral
Power Range0.37 to 22 kW
Protection ClassIP20
Output Frequency0 to 500 Hz
Braking ChopperBuilt-in
Control MethodScalar control, Vector control
Ambient Temperature-10 to +50 °C
Communication ProtocolsModbus, CANopen
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature
Cooling MethodAir-cooled
Number of Phases3-phase

Related product manuals