Note:
• The minimum specified wire size does not necessarily have sufficient current carrying
capacity at maximum load.
• The terminals do not accept a conductor that is one size larger than the maximum
specified wire size.
• The maximum number of conductors per terminal is 1.
Terminal data for the control cables
This table shows the control cable terminal data of the standard drive variant, that is,
the base unit with BMIO-01 I/O & Modbus module.
TorqueWire size
lbf·inN·mAWGmm
2
4.4…5.30.5…0.626…160.14…1.5
External EMC filters
The table shows the external EMC filters. See also EMC compatibility and motor cable
length and EMC compliance (IEC/EN 61800-3:2004 + A1:2012) (page 159).
EMC filter typeType
ACS380-
04xx-…
Schaffner order codeABB order code
1-phase U
N
= 230 V
FS 21754-6.1-07RFI-1102A4-1
FS 21754-16.1-07RFI-1203A7-1
FS 21754-16.1-07RFI-1204A8-1
FS 21754-16.1-07RFI-1206A9-1
FS 21754-16.1-07RFI-1207A8-1
3-phase U
N
= 230 V
FN 3258-16-44RFI-3202A4-2
FN 3258-16-44RFI-3203A7-2
FN 3258-16-44RFI-3204A8-2
FN 3258-16-44RFI-3206A9-2
FN 3258-16-44RFI-3207A8-2
FN 3258-16-44RFI-3209A8-2
FN 3258-30-33RFI-3312A2-2
FN 3258-30-33RFI-3317A5-2
FN 3258-30-33RFI-3325A0-2
FN 3258-100-35RFI-34032A-2
FN 3258-100-35RFI-34048A-2
150 Technical data