screwdriver or wrench with a set of suitable bits. For motor cable terminals, the
recommended screwdriver shaft length is 150 mm (5.9 in).
short flat head screwdriver for the I/O terminals
torque wrench
multimeter and voltage detector
personal protective equipment.
Measuring the insulation resistance
Measuring the insulation resistance of the drive
WARNING!
Do not do any voltage withstand or insulation resistance tests on any part of the
drive as testing can damage the drive. Every drive has been tested for insulation
between the main circuit and the chassis at the factory. Also, there are
voltage-limiting circuits inside the drive which cut down the testing voltage
automatically.
Measuring the insulation resistance of the input power cable
Before you connect the input power cable to the drive, measure its insulation resistance
according to local regulations.
Measuring the insulation resistance of the motor and motor cable
WARNING!
Obey the safety instructions of the drive. If you ignore them, injury or death,
or damage to the equipment can occur. If you are not a qualified electrical
professional, do not do installation or maintenance work.
1.
Do the steps in section Electrical safety precautions (page 17) before you start the
work.
2. Make sure that the motor cable is disconnected from the drive output terminals.
3. Measure the insulation resistance between each phase conductor and the protective
earth conductor. Use a measuring voltage of 1000 V DC. The insulation resistance
of an ABB motor must be more than 100 Mohm (reference value at 25 °C [77 °F]).
For the insulation resistance of other motors, refer to the manufacturer’s instructions.
Note: Moisture inside the motor reduces the insulation resistance. If you think that
there is moisture in the motor, dry the motor and do the measurement again.
90 Electrical installation North America

Table of Contents

Other manuals for ABB ACS380

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS380 and is the answer not in the manual?

ABB ACS380 Specifications

General IconGeneral
BrandABB
ModelACS380
CategoryDC Drives
LanguageEnglish

Related product manuals