2 - 20
Feed unit
Main unit
1 Needle plate A assembly removal
1. Remove the 2 screws 1, and then remove the needle plate A assembly 1.
1 1
1-1 Needle plate A ASSY disassembly
1. Remove the screw 1, and then remove the F gear stopper plate 1.
2. Remove the screw 2, and then remove the stopper plate 2.
21
21
2 Spring removal
1. Remove the spring .
S10
S10
3 Inner rotary hook bracket assembly removal
1. Remove the screw 1, and then remove the inner rotary hook bracket
assembly 1.
11