Clean UV LED Unit Quartz Window
Introduction
Dust and other debris as well as ink mist can accumulate on the UV LED unit windows. There is a
quartz window below each of the two sets of UV LED units.
When to do
Inspect and clean the UV LED unit windows once a month.
Equipment
Poly-Wipe lint-free Cloth, Isopropyl alcohol, scraper
Procedure
1.
Wipe the bottom of the quartz window with a lint-free cloth soaked in isopropyl alcohol.
2.
If you see any cured ink, it can be removed by scraping with a razor blade or similar tool held at a
45-degree angle, afterwards wipe with a lint-free cloth soaked in isopropyl alcohol.
Clean UV LED Unit Quartz Window