FINAL DRAFT - CISCO CONFIDENTIAL
8-9
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 8 Provisioning Using TL1
Set Alarm Thresholds
MAXCTMP Maximum
case
temperature
Integer
(20 to 70)
Read-write Alarm notifies operations personnel if
the case temperature of the
ONS 15216 EDFA2 is at a level that
may impact proper operation of the
optical network. Set the maximum
case temperature at a value that is
appropriate for intended application
and within product specifications.
Consult with the Cisco TAC to
determine the correct value for your
application. As a guideline, Cisco
recommends that maximum case
temperature value be set at 50
°C. Valid
entries are between 20 and 70
°C.
MAXCTMPHYST Maximum
case
temperature
hysteresis
Integer
(0 to 10)
Read-write Used to set the amount that the case
temperature of module must drop
below the maximum case temperature
alarm level before the alarm is cleared.
Set the hysteresis at a value that is
appropriate for the application so that
the alarm condition clears when the
input is stable. Consult with the Cisco
TAC to determine the correct value for
your application. As a guideline, Cisco
recommends setting the value at 1
°C.
Valid entries are between 0 and 10
°C.
Setting this value to 0 disables this
option.
MINCTMP Minimum
case
temperature
Integer
(–10 to 10)
Read-write Alarm notifies operations personnel if
the case temperature of the
ONS 15216 EDFA2 drops below a
level that impacts proper operation of
the optical network. The minimum
case temperature should be set at a
value that is appropriate for the
intended application and within
product specifications. Consult with
the Cisco TAC to determine the correct
value for your application. As a
guideline, Cisco recommends that
minimum case temperature be set at
1
°C. Valid entries are between –10 and
10
°C.
Table 8-1 Alarm Threshold Attribute Definitions (continued)
Attribute
Variable
Definition Syntax
Maximum
Access Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 15216 EDFA2 and is the answer not in the manual?

Cisco 15216 EDFA2 Specifications

General IconGeneral
BrandCisco
Model15216 EDFA2
CategoryNetwork Router
LanguageEnglish

Related product manuals