EasyManuals Logo
Home>Cisco>Network Router>15216 EDFA2

Cisco 15216 EDFA2 User Manual

Cisco 15216 EDFA2
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #89 background imageLoading...
Page #89 background image
FINAL DRAFT - CISCO CONFIDENTIAL
5-27
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 5 SNMP MIB Installation and Configuration
Retrieving Information
5.6.4 Case Temperature
5.6.4.1 Case Temperature Value
Command snmp attribute get local cerent15216EdfaPumpStatusAmbientTemp
Syntax Description snmp attribute get local cerent15216EdfaPumpStatusAmbientTemp pump#
Displays case temperature value (where pump# is the pump number).
The following command displays the temperature value (where pump# is the pump number) and other
pump status data:
• snmp row display local cerent15216EdfaPumpStatusAmbientTemp pump# command
The cerent15216EdfaPumpStatusAmbientTemp attribute of the cerent15216EdfaPumpStatusEntry
display command shows the case temperature (Example 5-13).
Example 5-13 cerent15216EdfaPumpStatusEntry Display Command
ash:hostname:ONS15216 EDFA2> snmp row display local cerent15216EdfaPumpStatusEntry 1
CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaPumpStatusEntry ::=
{
cerent15216EdfaPumpStatusPumpNum = 1;
cerent15216EdfaPumpStatusLaserChipTemp = 260;
cerent15216EdfaPumpStatusLaserChipTempSetpoint = 260;
cerent15216EdfaPumpStatusLaserTECCurrent = 20;
cerent15216EdfaPumpStatusLaserPower = 8503;
cerent15216EdfaPumpStatusLaserCurrent = 17010;
cerent15216EdfaPumpStatusAmbientTemp = 2272;
cerent15216EdfaPumpStatusDCVoltage = 52;
cerent15216EdfaPumpStatusInPoweruW = 250;
cerent15216EdfaPumpStatusInPowerdBm = -600;
cerent15216EdfaPumpStatusOutPowermW = 5000;
cerent15216EdfaPumpStatusOutPowerdBm = 1700;
cerent15216EdfaPumpStatusGain = 220;
};
Refer to Table 5-10 on page 5-18 for information about all of the parameters in the
cerent15216EdfaPumpStatusEntry table.
5.6.4.2 Case Temperature Alarm Threshold
5.6.4.2.1 CtmpMin
Command snmp attribute get local cerent15216EdfaCtmpMin
Syntax Description snmp attribute get local cerent15216EdfaCtmpMin
This command displays minimum case temperature alarm threshold.

Table of Contents