Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 9 TL1 Commands
Summary of Autonomous Alarms and Messages
Table 9-5 on page 9-4 summarizes the ONS 15216 EDFA2 autonomous events.
1. The messages for Loss of Signal (LOS), Gain Out of Range (GAIN), and Loss of Output Power (LPOUT) are prioritized (in
the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects
both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal (LOS) message
to the user. This prioritized filtering of alarms does not occur with the SNMP delivery of alarms of the ONS 15216 EDFA2.
2. A single power bus alarm is Minor. If the power system is in duplex mode and an alarm is raised on both power buses, the
second alarm is Critical.
Table 9-5 TL1 Autonomous Events
TL1 Autonomous
Message
Condition Type
(condtype)
Condition Descriptor
(conddescr)
Access
Identifier
(aid)
Condition
Effect
(condeff)
REPT EVT DWDM CTRLMODE1 Pump1 Control Mode
Changed
1TC
REPT EVT DWDM CTRLMODE2 Pump2 Control Mode
Changed
1TC
REPT EVT DWDM GAINCHGD Overall Gain Changed 1 TC
REPT EVT DWDM LOSHYSTCHGD LOS (loss of signal)
Hysteresis Changed
1TC
REPT EVT DWDM LOSTHCHGD LOS (loss of signal)
Threshold Changed
1TC
REPT EVT DWDM LPOUTCHGD Loss Of Output Power
Setpoint Changed
1TC
REPT EVT DWDM LPOUTDEVCHGD Lpout (loss of output
power) Deviation Changed
1TC
REPT EVT DWDM LPOUTHYSTCHGD Lpout (loss of output
power) Hysteresis Changed
1TC
REPT EVT DWDM PREATTCHGD Pre-attenuation Changed 1 TC
REPT EVT ENV PWRBUSMAXCHGD Power Bus Max (voltage)
Changed
PWR-A TC
REPT EVT ENV PWRBUSMINCHGD Power Bus Min (voltage)
Changed
PWR-A TC
REPT EVT ENV PWRBUSMODE Power Bus Mode Changed PWR-B TC
REPT EVT EQPT MAXCTMPCHGD Max Case Temperature
Changed
EQPT TC
REPT EVT EQPT
MAXCTMPHYSTCHGD
Max Ctmp (case temperature)
Hysteresis Changed
EQPT TC
REPT EVT EQPT MINCTMPCHGD Min Case Temperature
Changed
EQPT TC
REPT EVT EQPT
MINCTMPHYSTCHGD
Min Ctmp (case temperature)
Hysteresis Changed
EQPT TC
REPT EVT EQPT CUTOVERRESET (Software) Reset After
Cutover
EQPT TC