FINAL DRAFT - CISCO CONFIDENTIAL
9-43
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 9 TL1 Commands
TL1 Commands and Autonomous Messages
9.7.29 RTRV-COND-DWDM
Command RTRV-COND-DWDM
Generates a report on the condition (state) of DWDM alarms.
Note The messages for Loss of Signal (LOS), Gain Out of Range (GAIN), and Loss of Output Power
(LPOUT) are prioritized (in the order just listed) so that only one message can be delivered at one time.
For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at
the same time, it will deliver only the Loss of Signal (LOS) message to the user. This prioritized filtering
of alarms does not occur with the SNMP delivery of alarms of the ONS 15216 EDFA2.
Syntax
RTRV-COND-DWDM:[<tid>]:<aid>:<ctag>::[<condtype>][,,,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,<ccm>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,,<conddescr>"
;
Example 9-31 RTRV-COND-DWDM Command and Response
Amp01:ONS15216 EDFA2> RTRV-COND-DWDM:Amp01:ALL:229::LOS;
Amp01 2002-06-20 14:30:00
M 229 COMPLD
"1,DWDM:MJ,LOS,SA,6-20,14-25-30,,,\"Loss Of Signal\""
;
Table 9-36 RTRV-COND-DWDM Syntax Description
Parameter Syntax Description
aid 1 and ALL have same input effect.
1 Directly affecting the optical signal.
ALL Any or all of the preceding (command input only).
conddescr Detailed text description of the event. The conddescr is 1 to 64
characters of ASCII text. See condtype below.
condtype Condition type identifies the type of alarm (maps to
cerent15216EdfaLogEventID). Possible condtype and
corresponding conddescr (in quotes) are:
LOS Loss of Signal (input power) alarm
(cerent15216EdfaAlarmLpin).
GAIN Gain Out of Range alarm (cerent15216EdfaAlarmGain).
LPOUT Loss of Output Power alarm (cerent15216EdfaAlarmLpout).
date yyyy-mm-dd Date of origination of TL1 message.