Fan Performances ED34-862
180 FXDQ-PB / FXDQ-NB
8.2 FXDQ-NB
Note:
1. The remote controller can be used to switch between “HH”, “H” and “L”.
2. The air flow is set to “standard” before leaving the factory.
It is possible to switch between “standard ESP” and “high ESP” by the remote controller.
FXDQ40NBVE(T) FXDQ50NBVE(T)
FXDQ63NBVE(T)
8 117 9 10 12 13
10
(Pa)
5
6
External static pressure
50
Air flow rate (m
3
/min)
4
40
30
2
60
(Pa)
1
3
20
(mmH
2
O)
(mmH
2
O)
3
4
5
2
6
1
(mmH
2
O)
(mmH
2
O)
High
(standard ESP)
Low
(high ESP)
High
(high ESP)
Low
(standard
ESP)
Upper limit of
external static
pressure (high ESP)
Upper limit of
external static
pressure
(standard ESP)
Lower limit of
external static
pressure
(standard ESP)
Lower limit of
external static
pressure (high ESP)
3D046299C
1413129 118 10 15
10
(Pa)
5
6
External static pressure
50
Air flow rate (m
3
/min)
4
70
40
30
2
60
(Pa)
1
3
7
20
(mmH
2
O)
(mmH
2
O)
3
4
5
2
6
1
7
(mmH
2
O)
(mmH
2
O)
High
(standard ESP)
Low
(high ESP)
High
(high ESP)
Low
(standard
ESP)
Upper limit of external
static pressure (high
ESP)
Upper limit of external
static pressure
(standard ESP)
Lower limit of
external static
pressure
(standard ESP)
Lower limit of
external static
pressure (high ESP)
3D046300C
10
18
(Pa)
11
5
6
3
1913
External static pressure
4
5
50
Air flow rate (m
3
/min)
4
15
70
2
40
30
2
14
60
(Pa)
16
6
1
12
1
17
3
7
20
7
High
(standard ESP)
Low
(high ESP)
High
(high ESP)
Low
(standard
ESP)
(mmH
2
O)
(mmH
2
O)
(mmH
2
O)
(mmH
2
O)
Upper limit of
external static
pressure (high ESP)
Upper limit of external
static pressure (standard
ESP)
Lower limit of
external static
pressure
(standard ESP)
Lower limit of external
static pressure (high
ESP)
3D046301C
Все каталоги и инструкции здесь: http://splitoff.ru/tehn-doc.html

Table of Contents

Other manuals for Daikin VRV III

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin VRV III and is the answer not in the manual?

Daikin VRV III Specifications

General IconGeneral
TypeVRV (Variable Refrigerant Volume)
RefrigerantR410A
Energy EfficiencyHigh
ControlCentralized control systems, individual zone control
Operating Temperature Range (Cooling)-5°C to 46°C
Indoor Unit TypesCeiling Cassette, Ceiling Suspended, Wall Mounted, Floor Standing, Ducted
Power Supply380-415V, 50/60Hz, 3-Phase (depending on model)

Related product manuals