Fan Performances ED34-862
262 FXMQ-P
8.2 “Air Flow Auto Adjustment” Characteristics
FXMQ20P / 25PVE
FXMQ32PVE
9.0
100
8.07.06.0 8.55.5 6.5
Lower limit of ESP
(Pa)
(Pa)
7.5
External static pressure
0
10.59.5 10.0
50
150
Lower limit
of ESP by
airflow auto
adjustment
Upper limit of ESP
(NOTE 8)
HH
Upper limit
of ESP by
airflow auto
adjustment
L
H
Air flow(m
3
/min)
(mmH
2O)
(mmH2O)
10
5
15
0
(mmH
2O)
15
10
5
0
(mmH
2O)
3D062539
Notes:
1. As for this machine, less than 10% of the volume of
blow-off air is automatically adjusted to the rated
quantity by airflow auto adjustment at the time of
installation.
2. After duct construction completion, please perform
local setting "airflow auto adjustment" by remote
controller.
3. About the local setting method of the "airflow auto
adjustment", look at the installation manual which is
attached to an indoor unit.
4. External static pressure that can adjust by "airflow
auto adjustment" function is 30Pa-100Pa (When air
flow is HH).
5. It is not operated auto adjustment, operated in air
flow that is different from rated quantity in the case
of use out of external static pressure range
mentioned above.
6. This figure shows a fan characteristics at the time
of "HH" "H" and "L".
7. The remote controller can be used to change "HH"
"H" and "L".
8. ESP : external static pressure.
Notes:
1. As for this machine, less than 10% of the volume of
blow-off air is automatically adjusted to the rated
quantity by airflow auto adjustment at the time of
installation.
2. After duct construction completion, please perform
local setting "airflow auto adjustment" by remote
controller.
3. About the local setting method of the "airflow auto
adjustment", look at the installation manual which is
attached to an indoor unit.
4. External static pressure that can adjust by "airflow
auto adjustment" function is 30Pa-100Pa (When air
flow is HH).
5. It is not operated auto adjustment, operated in air
flow that is different from rated quantity in the case
of use out of external static pressure range
mentioned above.
6. This figure shows a fan characteristics at the time
of "HH" "H" and "L".
7. The remote controller can be used to change "HH"
"H" and "L".
8. ESP : external static pressure.
7.5
50
9.5
6.0 8.5 10.5
9.0
(Pa)
0
150
10.0 11.0
100
8.0
(Pa)
6.5 7.0
External static pressure
Lower limit of ESP
L
Upper limit
of ESP by
airflow auto
adjustment
Lower limit
of ESP by
airflow auto
adjustment
HH
Air flow(m
3
/min)
Upper limit of ESP
(NOTE 8)
5
15
0
10
(mmH
2O)
(mmH2O)
(mmH
2O)
0
15
10
5
(mmH
2O)
H
3D062540
Все каталоги и инструкции здесь: http://splitoff.ru/tehn-doc.html

Table of Contents

Other manuals for Daikin VRV III

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin VRV III and is the answer not in the manual?

Daikin VRV III Specifications

General IconGeneral
TypeVRV (Variable Refrigerant Volume)
RefrigerantR410A
Energy EfficiencyHigh
ControlCentralized control systems, individual zone control
Operating Temperature Range (Cooling)-5°C to 46°C
Indoor Unit TypesCeiling Cassette, Ceiling Suspended, Wall Mounted, Floor Standing, Ducted
Power Supply380-415V, 50/60Hz, 3-Phase (depending on model)