ED34-862 Dimensions
FXFQ-P 51
2
3. Dimensions
FXFQ25P / 32P / 40P / 50PVE
Unit (mm)
C/L
C/L
157
160
55
25
10
80
183
157
160
55
20
124
40
160
60
350
125
50
165
80
55
95
124
4
124
90
95
110
124
85
95
81
160
81 85
124
850
340
840
213
42
256
350
350
256
2
80
90
150
1
130
64
109
5
157
246
280
55
350
50
80
124
110
95
124
330
157
105
175
110
840
124
3
300
OR LESS
C
780 (SUSPENTION POSITION)
710 (SUSPENTION POSITION)
420
860~910 (CELING OPENING SPACE) (NOTE 4)
420
9
860~910 (CELING OPENING SPACE) (NOTE 4)
B
2 × 100=200
2 × 100=200
(ROUND SHAPE TYPE)
CONNECTION POSITION
OF BRANCH DUCT
16-M4 HOLE
(SQUARE-SHAPED TYPE)
CONNECTION POSITION
OF BRANCH DUCT
2 × 100=200
C/L
(KNOCK HOLE)
φ
100
(ROUND SHAPE TYPE)
CONNECTION POSITION
OF BRANCH DUCT
20-M4
PREPARED HOLE
(SQUARE-SHAPED TYPE)
CONNECTION POSITION
OF BRANCH DUCT
(DIRECT INSTALLATION TYPE)
CONNECTION POSITION
OF FRESH AIR INTAKE KIT
ADJUSTABLE (0~675)
(SQUARE-SHAPED TYPE)
CONNECTION POSITION
OF BRANCH DUCT
16-M4 PREPARED HOLE
4-M8~M10
SUSPENTION BOLT
(ROUND SHAPE TYPE)
CONNECTION POSITION
OF BRANCH DUCT
35 OR LESS (NOTE 4)
2 × 100=200
(ROUND SHAPE TYPE)
CONNECTION POSITION
OF BRANCH DUCT
A
20-M4 PREPARED HOLE
35 OR LESS
(NOTE 4)
(SQUARE-SHAPED TYPE)
CONNECTION POSITION
OF BRANCH DUCT
FOR HEIGHT INSTALLATION
(REQUIRED SPACE)
1500 OR MORE
FROM THE FLOOR SIDE 2500 OR MORE
NOTE) 1. STICKING LOCATION FOR MANUFACTURE'S LABEL
MANUFACTURE'S LABEL FOR INDOOR UNIT:
SUCTION GRILL INNER SIDE'S ELECTRIC COMPONENTS BOX'S LID SURFACE
MANUFACTURE'S LABEL FOR DECORATION PANEL:
DECORATION PANEL'S CORNER DECORATION COVER INNER SURFACE
2. IN CASE OF USING WIRELESS REMOTE CONTROLLER, THIS POSITION WILL
BE A SIGNAL RECEIVER. REFER TO THE DRAWING OF WIRELESS REMOTE
CONTROLLER IN DETAIL.
3. WHEN THE TEMPERATURE AND HUMIDITY IN THE CEILING EXCEED 30˚C
AND RH 80% OR THE FRESH AIR IS INDUCTED INTO THE CEILING OR THE
UNIT CONTINUES 24 HOUR OPERATION, AN ADDITIONAL INSULATION
(THICKNESS 10mm OR MORE OF GLASSWOOL OR POLYETHYLENE FORM) IS
REQUIRED.
4. THOUGH THE INSTALLATION IS ACCEPTABLE UP TO MAXIMUM OF 910mm
SQUARE CEILING OPENING, KEEP THE CLEARANCE OF 35mm OR LESS
BETWEEN THE INDOOR UNIT AND THE CEILING OPENING SO THAT THE
PANEL OVERLAP ALLOWANCE CAN BE ENSURED.
5. PLEASE DO NOT PLACE THE THING BEEN DAMP AND TROUBLED UNDER AN
INDOOR UNIT.
WHEN THE CASE WHERE HUMIDITY IS 80% OR MORE, AND THE DRAIN
OUTLET ARE CHOKED UP AND THE AIR FILTER ARE DIRTY, DEW MAY FALL.
PIPE CONNECTION SIDE
DRAIN CONNECTION SIDE
NOTE 2
6
950
8
7
950
A ARROW VIEW
B ARROW VIEW
C ARROW VIEW
BYCP125K-W1 FRESH WHITE 6.5Y 9.5/0.5
ITEM PART NAME
SUCTION GRILLE
DRAIN HOSE (ACCESSORY)
DRAIN PIPE CONNECTION
CORNER DECORATION COVER
CONNECTION WIRING/
REMOTE CONTROL WIRING
CONNECTION
GAS PIPE CONNECTION
AIR-OUTLET
POWER-SOURCE WIRING
AND A UNIT WIRING CONNECTION
LIQUID PIPE CONNECTION
9
8
7
6
5
4
3
2
1
• DECORATION PANEL
• REQUIRED SPACE
1500mm OR MORE*
1500mm OR MORE*
1500mm OR MORE*
1500mm OR MORE*
200mm OR MORE*
200mm OR MORE*
* WHEN THE BLOW-OFF GRILL IS CLOSING. THE REQUIRED
SPACE IS 500mm OR MORE.
WHEN UNITING AND CLOSING A CORNER PART (BOTH RIGHT
AND LEFT OF THE BLOW-OFF GRILL TO CLOSE), IT IS 200mm
OR MORE.
φ 12.7 (FLARE CONNECTION)
φ 6.4 (FLARE CONNECTION)
VP25 (OD φ 32)
LOCAL CONNECTION OD φ 32
(OUTLET) (UNIT CONNECTION
OD φ 26)
REMARK
3D060187
Все каталоги и инструкции здесь: http://splitoff.ru/tehn-doc.html

Table of Contents

Other manuals for Daikin VRV III

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin VRV III and is the answer not in the manual?

Daikin VRV III Specifications

General IconGeneral
TypeVRV (Variable Refrigerant Volume)
RefrigerantR410A
Energy EfficiencyHigh
ControlCentralized control systems, individual zone control
Operating Temperature Range (Cooling)-5°C to 46°C
Indoor Unit TypesCeiling Cassette, Ceiling Suspended, Wall Mounted, Floor Standing, Ducted
Power Supply380-415V, 50/60Hz, 3-Phase (depending on model)