Page #142 background imageLoading...
Page #142 background image
•
•
•
Option
Name
Description
[6]
Poly 5'order
Connects the CAM table points with a 5
th
order polynomial. At least 3 consecutive CAM table points of
this type are required to use this selection.
[8]
Sine
Connects the CAM table points with a full sine wave.
[9]
Cosine
Connects the CAM table points with a full cosine wave.
[10]
End
Always select this option for the last point of the curve.
Parameter 3-39 CAM Follower Gain
Table 221: Parameter 3-39 CAM Follower Gain
3-39 CAM Follower Gain
Default value: 100.0
Parameter type: Range, 0.0 - 500.0%
Setup: All setups
Conversion index: -1
Data type: Uint16
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
The follower table is multiplied by this gain which can be adjusted while running.
5.4.5 3-4* Ramp 1
For each of the 4 ramps (parameter groups 3-4* Ramp 1, 3-5* Ramp 2, 3-6* Ramp 3, and 3-7* Ramp 4) configure the ramp parameters:
Ramp type
Ramping times (duration of acceleration and deceleration)
Level of jerk compensation for S-ramps
Start by setting the linear ramping times corresponding to
Illustration 51 and Illustration 52.
P 3-*2
Ramp (X) Down
Time (Dec)
P 4-13
High-limit
RPM
Reference
n
s
P 4-11
Low limit
t
dec
Time
P 3-*1
Ramp (X)Up
Time (Acc)
t
acc
e30ba872.11
Illustration 51: Linear Ramping Times
If S-ramps are selected, set the level of non-linear jerk compensation required. Set jerk compensation by defining the proportion of
ramp-up and ramp-down times where acceleration and deceleration are variable (that is, increasing or decreasing). The S-ramp ac-
celeration and deceleration settings are defined as a percentage of the actual ramp time.
AU275636650261en-000101 / 130R0334142 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals