Parameter 17-58 Encoder Sim. Resolution Adv.
Table 934: Parameter 17-58 Encoder Sim. Resolution Adv.
17-58 Encoder Sim. Resolution Adv.
Default value: 0
Parameter type: Range, 0 - 16384
Setup: 1 setup
Conversion index: 0
Data type: Uint16
Change during operation: False
Set the encoder simulation resolution as a continuous value in steps of 1. This parameter is only active when [5] Enable encoder sim.
adv. is selected in parameter 17-56 Encoder Sim. Resolution.
Parameter 17-59 Resolver Interface
Table 935: Parameter 17-59 Resolver Interface
17-59 Resolver Interface
Default value: [0] Disabled
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: False
Activate the VLT® Resolver Input MCB 103 when the resolver parameters are selected. To avoid damage to resolvers, adjust parame-
ter 17-50 Poles and parameter 17-53 Transformation Ratio before enabling this parameter.
Option
Name
Description
[0]*
Disabled
[1]
512
5.17.6 17-6* Monitoring and Application
N O T I C E
The following parameters are only available in FC 302:
Parameter 17-67 Raw Inc. Quad Counter
Parameter 17-68 Raw Abs. Pos. Low
Parameter 17-69 Raw Abs. Pos. High
This parameter group is for selecting extra functions when VLT® Encoder MCB 102 or VLT® Resolver Input MCB 103 is fitted into
option slot B as speed feedback. Monitoring and application parameters cannot be adjusted while the motor is running.
Parameter 17-60 Feedback Direction
Table 936: Parameter 17-60 Feedback Direction
17-60 Feedback Direction
Default value: [0] Clockwise
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: False
N O T I C E
This parameter cannot be adjusted while the motor is running.
Change the detected encoder rotation direction without changing the wiring to the encoder.
AU275636650261en-000101 / 130R0334 | 523Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals