Parameter 32-51 MCO 302 Last Will
Table 1141: Parameter 32-51 MCO 302 Last Will
Change during operation: True
Parameter 32-52 Source Master
Table 1142: Parameter 32-52 Source Master
Default value: [1] Encoder 1 X56
Change during operation: True
5.25.4 32-6* PID Controller
Parameter 32-60 Proportional Factor
Table 1143: Parameter 32-60 Proportional Factor
32-60 Proportional Factor
Parameter type: Range, 0 - 100000
Change during operation: True
The proportional factor indicates the linear correction factor with which the deviation between the current set and actual position is
evaluated. The motor speed is then corrected accordingly.
Parameter 32-61 Derivative Factor
Table 1144: Parameter 32-61 Derivative Factor
Parameter type: Range, 0 - 100000
Change during operation: True
The derivative value is the correction factor with which the changing speed of a motor position error is evaluated. The derivative
value prevents overswing due to a high P-share and dampens the system.