This parameter is read-only. It shows the physical (MAC) address of the option.
5.12.2 12-1* Ethernet Link Parameters
Parameter 12-10 Link Status
Table 613: Parameter 12-10 Link Status
Default value: [0] No link
Change during operation: True
This parameter is read-only. It shows the link status of the Ethernet ports. Index [0] is used for port 1, and index [1] is used for port 2.
For EtherCAT, index [0] is for the in-port, and index [1] is for the out-port.
Parameter 12-11 Link Duration
Table 614: Parameter 12-11 Link Duration
Default value: Size related
Parameter type: Range, Size related
Data type: TimeDifferenceWithDateIndication
Change during operation: True
Shows the duration of the present link on each port in dd:hh:mm:ss.
Parameter 12-12 Auto Negotiation
Table 615: Parameter 12-12 Auto Negotiation
Default value: Size related
Change during operation: True
Configures auto negotiation of Ethernet link parameters, for each port: ON or OFF. Link Speed and Link Duplex can be configured in
parameter 12-13 Link Speed and parameter 12-14 Link Duplex.
Parameter 12-13 Link Speed
Table 616: Parameter 12-13 Link Speed
Default value: Size related
Change during operation: True
Forces the link speed for each prot in 10 Mbps or 100 Mbps. If parameter 12-12 Auto Negotiation is set to [0] On, this parameter is
read-only and shows the actual link speed. If no link is present, None is shown.