Some systems call for avoiding certain output speeds due to resonance problems in the system. Enter the upper limits of the speeds
to be avoided.
Parameter 4-63 Speed Bypass To [Hz]
Table 305: Parameter 4-63 Bypass Speed To [Hz]
4-63 Bypass Speed To [Hz]
Default value: Size related
Parameter type: Range, 0 - setting in par. 4-14 Hz, Array [4]
Setup: All setups
Conversion index: -1
Data type: Uint16
Change during operation: True
Some systems require that certain output frequencies or speeds are avoided due to resonance problems in the system. Enter the
upper limits of the speeds to be avoided.
5.5.7 4-7* Position Monitor
Parameter 4-70 Position Error Function
Table 306: Parameter 4-70 Position Error Function
4-70 Position Error Function
Default value: [0] Disabled
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Select the function which is activated when the position error exceeds the maximum allowed value. Position error is the difference
between the actual position and the commanded position. The position error is the input for the position PI controller.
Option
Name
Description
[0]*
Disabled
The drive does not monitor the position error.
[1]
Warning
The drive issues a warning when the maximum allowed position error is exceeded. The drive
continues operation.
[2]
Trip
The drive trips when the maximum allowed position error is exceeded.
[3]
Jog
[4]
Freeze Output
[5]
Max Speed
[6]
Switch to Open Loop
[7]
Select setup 1
[8]
Select setup 2
[9]
Select setup 3
[10]
Select setup 4
[11]
Stop & Trip
[12]
Trip/Warning
[13]
Trip/Catch
AU275636650261en-000101 / 130R0334 | 169Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals