Parameter 0-51 Set-up Copy
Table 35: Parameter 0-51 Set-up Copy
Default value: [0] No copy
Change during operation: False
Copies all parameters in the present programming setup (defined in parameter 0-11 Edit Set-up) to
set-up 1.
Copies all parameters in the present programming setup (defined in parameter 0-11 Edit Set-up) to
set-up 2.
Copies all parameters in the present programming setup (defined in parameter 0-11 Edit Set-up) to
set-up 3.
Copies all parameters in the present programming setup (defined in parameter 0-11 Edit Set-up) to
set-up 4.
Copies the parameters in the present setup to each of the setups 1 to 4.
5.1.7 0-6* Password
Parameter 0-60 Main Menu Password
Table 36: Parameter 0-60 Main Menu Password
Parameter type: Range, -9999 - 9999
Change during operation: True
Define the password for access to the Main Menu via the [Main Menu] key. If parameter 0-61 Access to Main Menu w/o Password is set
to [0] Full access, this parameter is ignored.
Parameter 0-61 Access to Main Menu w/o Password
Table 37: Parameter 0-61 Access to Main Menu w/o Password
0-61 Access to Main Menu w/o Password
Default value: [0] Full access
Change during operation: True
Disables password defined in parameter 0-60 Main Menu Password.
Prevent unauthorized editing of Main Menu parameters.
Prevent unauthorized viewing and editing of Main Menu parameters.
Read-only functions for parameters on fieldbus and/or FC standard bus.
AU275636650261en-000101 / 130R0334 | 57Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide