Shows the actual position error in position units defined in parameter group 17-7* Position Scaling. Position error is the difference
between the actual position and the commanded position. The position error is the input for the position PI controller.
Parameter 16-09 Customer Readout
Table 830: Parameter 16-09 Customer Readout
Default value: 0 CustomReadoutUnit
Parameter type: Range, 0 CustomReadoutUnit -
999999.99 CustomReadoutUnit
Change during operation: False
View the value of custom readout from parameter 0-30 Unit for Userdefined Readout to parameter 0-32 Custom Readout Max Value.
5.16.2 16-1* Motor Status
N O T I C E
The following parameter is only available in FC 302:
Parameter 16-24 Calibrated Stator Resistance
Parameter 16-10 Power [kW]
Table 831: Parameter 16-10 Power [kW]
Parameter type: Range, 0 - 10000 kW
Change during operation: False
Shows motor power in kW. The value shown is calculated based on the actual motor voltage and motor current. The value is fil-
tered, and therefore approximately 1.3 s may pass from when an input value changes to when the data readout values change. The
resolution of readout value on fieldbus is in 10-W steps. The base unit is in W.
Parameter 16-11 Power [hp]
Table 832: Parameter 16-11 Power [hp]
Parameter type: Range, 0 - 10000 hp
Change during operation: False
Shows motor power in hp. The value shown is calculated based on the actual motor voltage and motor current. The value is filtered,
and therefore approximately 1.3 ms may pass from when an input value changes to when the data readout values change.
Parameter 16-12 Motor Voltage
Table 833: Parameter 16-12 Motor Voltage
Parameter type: Range, 0 - 6000 V
Change during operation: False
View the motor voltage, a calculated value used for controlling the motor.