EasyManuals Logo
Home>Danfoss>DC Drives>VLT AutomationDrive FC 301

Danfoss VLT AutomationDrive FC 301 Programming Guide

Danfoss VLT AutomationDrive FC 301
722 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #498 background imageLoading...
Page #498 background image
-
N O T I C E
This parameter is only valid with sofware version 48.XX.
Shows the actual position error in position units defined in parameter group 17-7* Position Scaling. Position error is the difference
between the actual position and the commanded position. The position error is the input for the position PI controller.
Parameter 16-09 Customer Readout
Table 830: Parameter 16-09 Customer Readout
16-09 Customer Readout
Default value: 0 CustomReadoutUnit
Parameter type: Range, 0 CustomReadoutUnit -
999999.99 CustomReadoutUnit
Setup: All setups
Conversion index: -2
Data type: Int32
Change during operation: False
View the value of custom readout from parameter 0-30 Unit for Userdefined Readout to parameter 0-32 Custom Readout Max Value.
5.16.2 16-1* Motor Status
N O T I C E
The following parameter is only available in FC 302:
Parameter 16-24 Calibrated Stator Resistance
Parameter 16-10 Power [kW]
Table 831: Parameter 16-10 Power [kW]
16-10 Power [kW]
Default value: 0 kW
Parameter type: Range, 0 - 10000 kW
Setup: All setups
Conversion index: 1
Data type: Int32
Change during operation: False
Shows motor power in kW. The value shown is calculated based on the actual motor voltage and motor current. The value is fil-
tered, and therefore approximately 1.3 s may pass from when an input value changes to when the data readout values change. The
resolution of readout value on fieldbus is in 10-W steps. The base unit is in W.
Parameter 16-11 Power [hp]
Table 832: Parameter 16-11 Power [hp]
16-11 Power [hp]
Default value: 0 hp
Parameter type: Range, 0 - 10000 hp
Setup: All setups
Conversion index: -2
Data type: Int32
Change during operation: False
Shows motor power in hp. The value shown is calculated based on the actual motor voltage and motor current. The value is filtered,
and therefore approximately 1.3 ms may pass from when an input value changes to when the data readout values change.
Parameter 16-12 Motor Voltage
Table 833: Parameter 16-12 Motor Voltage
16-12 Motor Voltage
Default value: 0 V
Parameter type: Range, 0 - 6000 V
Setup: All setups
Conversion index: -1
Data type: Uint16
Change during operation: False
View the motor voltage, a calculated value used for controlling the motor.
AU275636650261en-000101 / 130R0334498 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals