Parameter 17-34 HIPERFACE Baudrate
Table 923: Parameter 17-34 HIPERFACE Baudrate
Change during operation: False
N O T I C E
This parameter cannot be adjusted while the motor is running.
Select the baud rate of the attached encoder. The parameter is only accessible when parameter 17-20 Protocol Selection is set to [1]
HIPERFACE.
5.17.4 17-4* Fieldbus Reference 2
Parameter 17-40 Fieldbus Sync. Delta
Table 924: Parameter 17-40 Fieldbus Sync. Delta
17-40 Fieldbus Sync. Delta
Parameter type: Range, -2147483648 - 2147483647
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Shows the fieldbus synchronizing master position change = master speed when transferred by PCD from fieldbus master.
Parameter 17-41 Fieldbus Profile Velocity
Table 925: Parameter 17-41 Fieldbus Profile Velocity
17-41 Fieldbus Profile Velocity
Parameter type: Range, 0 - 2147483647 pu/s
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Velocity reference for the profile generator in positioning mode or when using Mode of operation and Profile ositioning mode.
AU275636650261en-000101 / 130R0334520 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide