Parameter 17-21 Resolution (Positions/Rev)
Table 918: Parameter 17-21 Resolution (Positions/Rev)
17-21 Resolution (Positions/Rev)
Default value: Size related
Parameter type: Range, 4 - 1073741824
Setup: All setups
Conversion index: 0
Data type: Uint32
Change during operation: False
Select the resolution of the absolute encoder, that is the number of counts per revolution. The value depends on setting in parame-
ter 17-20 Protocol Selection.
Parameter 17-22 Multiturn Revolutions
Table 919: Parameter 17-22 Multiturn Revolutions
17-22 Multiturn Revolutions
Default value: 1
Parameter type: Range, 1 - 16777216
Setup: All setups
Conversion index: 0
Data type: Uint32
Change during operation: False
Select the number of multi-turn revolutions. Select value 1 for single-turn type encoders.
Parameter 17-24 SSI Data Length
Table 920: Parameter 17-24 SSI Data Length
17-24 SSI Data Length
Default value: 13
Parameter type: Range, 1 - 32
Setup: All setups
Conversion index: 0
Data type: Uint8
Change during operation: False
Set the number of bits for the SSI telegram. Select 13 bits for singleturn encoders and 25 bits for multiturn encoders.
Parameter 17-25 Clock Rate
Table 921: Parameter 17-25 Clock Rate
17-25 Clock Rate
Default value: 260 kHz
Parameter type: Range, 100 - 260 kHz
Setup: All setups
Conversion index: 3
Data type: Uint16
Change during operation: False
Set the SSI clock rate. With long encoder cables, the clock rate must be reduced.
Parameter 17-26 SSI Data Format
Table 922: Parameter 17-26 SSI Data Format
17-26 SSI Data Format
Default value: [0] Gray code
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: False
Option
Name
Description
[0]*
Gray code
[1]
Binary code
Set the data format of the SSI data.
AU275636650261en-000101 / 130R0334 | 519Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals