5.9.2 8-1* Ctrl. Word Settings
Parameter 8-10 Control Word Profile
Table 503: Parameter 8-10 Control Word Profile
8-10 Control Word Profile
Default value: Size related
Change during operation: True
Select the interpretation of the control and status words corresponding to the installed fieldbus. Only the selections valid for the
fieldbus installed in slot A are visible in the LCP display. For guidelines in selection of [0] FC profile and [1] PROFIdrive profile, refer to
the product-specific design guide. For more guidelines in the selection of [1] PROFIdrive profile, refer to the Installation Guide for the
installed fieldbus.
N O T I C E
This option is only available with software version 48.XX.
Assigns motion-specific functions to various control and status word bits. This option is available
when [9] Positioning or [10] Synchronization is selected in parameter 1-00 Configuration Mode.
Parameter 8-13 Configurable Status Word STW
Table 504: Parameter 8-13 Configurable Status Word STW
8-13 Configurable Status Word STW
Default value: Size related
Parameter type: Option, Array [16]
Change during operation: True
Select the interpretation of the control and status words corresponding to the installed fieldbus. Only the selections valid for the
fieldbus installed in slot A are visible in the LCP display. For more guidelines in the selection of [1] PROFIdrive profile, refer to the
Installation Guide for the installed fieldbus.
Dependent on the profile set in parameter 8-10 Control Profile.
The input goes high whenever Alarm 68 Safe Stop Activated is active and goes low
whenever Alarm 68 Safe Stop Activated is not activated.