Parameter 10-13 Warning Parameter
Table 588: Parameter 10-13 Warning Parameter
10-13 Warning Parameter
Default value: 0
Parameter type: Range, 0 - 65535
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
View a DeviceNet-specific warning word. One bit is assigned to every warning. Refer to the VLT® DeviceNet MCA 104 Installation
Guide for further information.
Table 589: Warning Bits
Bit
Description
0
Bus not active
1
Explicit connection timeout
2
I/O connection
3
Retry limit reached
4
Actual is not updated
5
CAN bus off
6
I/O send error
7
Initialization error
8
No bus supply
9
Bus off
10
Error passive
11
Error warning
12
Duplicate MAC ID error
13
RX queue overrun
14
TX queue overrun
15
CAN overrun
Parameter 10-14 Net Reference
Table 590: Parameter 10-14 Net Reference
10-14 Net Reference
Default value: [0] Off
Parameter type: Option
Setup: 2 setups
Conversion index: –
Data type: Uint8
Change during operation: True
Select the reference source in instances 21/71 and 20/70.
Option
Name
Description
[0]*
Off
[1]
On
AU275636650261en-000101 / 130R0334 | 337Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals