See parameter group 13-1* Comparators.
See parameter group 13-1* Comparators.
See parameter group 13-1* Comparators.
See parameter group 13-1* Comparators.
See parameter group 13-1* Comparators.
X47/VLT® Extended Relay Card MCB 113.
X47/VLT® Extended Relay Card MCB 113.
X47/VLT® Extended Relay Card MCB 113.
X47/VLT® Extended Relay Card MCB 113.
X34/VLT® Relay Card MCB 105.
X34/VLT® Relay Card MCB 105.
X34/VLT® Relay Card MCB 105.
N O T I C E
This option is only available with software version 48.2X or newer.
Homing is completed with the selected homing function (parameter 17-80 Homing Function).
N O T I C E
This option is only available with software version 48.2X or newer.
Positioning is completed and the on target signal is sent when the actual position is within
parameter 3-05 On Reference Window for the duration of parameter 3-09 On Target Time and
the actual speed does not exceed parameter 3-05 On Reference Window.
N O T I C E
This option is only available with software version 48.2X or newer.
The position error exceeds the value in parameter 4-71 Maximum Position Error for the time
set in parameter 4-72 Position Error Timeout.
N O T I C E
This option is only available with software version 48.2X or newer.
The position is outside the limits set in parameter 3-06 Minimum Position and parameter 3-07
Maximum Position.
AU275636650261en-000101 / 130R0334412 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide