Parameter 16-18 Motor Thermal
Table 839: Parameter 16-18 Motor Thermal
16-18 Motor Thermal
Default value: 0%
Parameter type: Range, 0 - 100%
Setup: All setups
Conversion index: 0
Data type: Uint8
Change during operation: False
View the calculated thermal load on the motor. The cutout limit is 100%. The basis for calculation is the ETR function selected in
parameter 1-90 Motor Thermal Protection.
Parameter 16-19 Thermistor Sensor Temperature
Table 840: Parameter 16-19 Thermistor Sensor Temperature
16-19 Thermistor Sensor Temperature
Default value: 0 °C
Parameter type: Range, 0 - 0 °C
Setup: All setups
Conversion index: 100
Data type: Int16
Change during operation: False
Returning the actual temperature on KTY sensor built into the motor. See parameter group 1-9* Motor Temperature.
Parameter 16-20 Motor Angle
Table 841: Parameter 16-20 Motor Angle
16-20 Motor Angle
Default value: 0
Parameter type: Range, 0 - 65535
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
View the current encoder/resolver angle offset relative to the index position. The value range of 0–65535 corresponds to 0–2xpi
(radian).
Parameter 16-21 Torque [%] High Res.
Table 842: Parameter 16-21 Torque [%] High Res.
16-21 Torque [%] High Res.
Default value: 0%
Parameter type: Range, -200 - 200%
Setup: All setups
Conversion index: -1
Data type: Int16
Change during operation: False
The value shown is the torque in percent of nominal torque, with sign and 0.1% resolution, applied to the motor shaft.
Parameter 16-22 Torque [%]
Table 843: Parameter 16-22 Torque [%]
16-22 Torque [%]
Default value: 0%
Parameter type: Range, -200 - 200%
Setup: All setups
Conversion index: 1
Data type: Int16
Change during operation: False
The value shown is the torque in percent of nominal torque, with sign, applied to the motor shaft.
Parameter 16-23 Motor Shaft Power [kW]
Table 844: Parameter 16-23 Motor Shaft Power [kW]
16-23 Motor Shaft Power [kW]
Default value: 0 kW
Parameter type: Range, 0 - 10000 kW
Setup: All setups
Conversion index: -1
Data type: Int32
Change during operation: True
AU275636650261en-000101 / 130R0334500 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals