Parameter 18-24 Marker Pos. Offset
Table 984: Parameter 18-24 Marker Pos. Offset
18-24 Marker Pos. Offset
Default Value: 0
Parameter Type: Range, -2147483648 - 2147483647 [pu]
Setup: All setups
Conversion Index: 0
Data Type: Int32
Change during operation: True
N O T I C E
This parameter is only available in software version 48.8X.
Shows the position difference between master marker and follower marker in position units as defined in parameter group 17-0*
Position Scaling. The value is calculated by: Marker Pos. Offset = Master marker position – Follower marker position.
Parameter 18-25 Latched Actual Pos.
Table 985: Parameter 18-25 Latched Actual Pos.
18-25 Latched Actual Pos.
Default value: 0
Parameter type: Range, -2147483648 - 2147483647 [pu]
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
N O T I C E
This parameter is only available in software version 48.8X.
Shows the actual position latched by the latest detected sensor, that is home sensor, touch sensor, or follower marker.
Parameter 18-26 Actual Velocity [pu/s]
Table 986: Parameter 18-26 Actual Velocity [pu/s]
18-26 Actual Velocity [pu/s]
Default value: 0
Parameter type: Range, -2147483648 - 2147483647 [pu]
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
N O T I C E
This parameter is only available in software version 48.8X.
Shows the actual speed in position units per second.
Parameter 18-27 Safe Opt. Speed
Table 987: Parameter 18-27 Safe Opt. Speed
18-27 Safe Opt. Speed
Default value: 0 RPM
Parameter type: Range, -30000 - 30000 RPM
Setup: All setups
Conversion index: 67
Data type: Int32
Change during operation: True
Shows the speed that the drive estimates and sends to the VLT® Safety Option MCB 15X.
AU275636650261en-000101 / 130R0334542 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals