Parameter 18-24 Marker Pos. Offset
Table 984: Parameter 18-24 Marker Pos. Offset
Parameter Type: Range, -2147483648 - 2147483647 [pu]
Change during operation: True
N O T I C E
This parameter is only available in software version 48.8X.
Shows the position difference between master marker and follower marker in position units as defined in parameter group 17-0*
Position Scaling. The value is calculated by: Marker Pos. Offset = Master marker position – Follower marker position.
Parameter 18-25 Latched Actual Pos.
Table 985: Parameter 18-25 Latched Actual Pos.
18-25 Latched Actual Pos.
Parameter type: Range, -2147483648 - 2147483647 [pu]
Change during operation: True
N O T I C E
This parameter is only available in software version 48.8X.
Shows the actual position latched by the latest detected sensor, that is home sensor, touch sensor, or follower marker.
Parameter 18-26 Actual Velocity [pu/s]
Table 986: Parameter 18-26 Actual Velocity [pu/s]
18-26 Actual Velocity [pu/s]
Parameter type: Range, -2147483648 - 2147483647 [pu]
Change during operation: True
N O T I C E
This parameter is only available in software version 48.8X.
Shows the actual speed in position units per second.
Parameter 18-27 Safe Opt. Speed
Table 987: Parameter 18-27 Safe Opt. Speed
Parameter type: Range, -30000 - 30000 RPM
Change during operation: True
Shows the speed that the drive estimates and sends to the VLT® Safety Option MCB 15X.