Selects input for home sensor.
Selects input for home sensor.
Selects input for touch probe sensor.
Selects input for touch probe sensor.
Selects speed mode when parameter 1-00 Configuration
Mode is set to [9] Positioning or [10] Synchronization.
Changes the sign of the set target position. For example,
if the set target is 1000, the activation of this option
changes the value to -1000.
Activates position-controlled virtual master
Master position = parameter 17-88 Master Home
Set vir. mas. pos. to
actual
Virtual master position = parameter 16-06 Actual Position
Activation of new CAM table while running
Master marker signal for marker synchronization, rising
edge
Master marker signal for marker synchronization, falling
edge
Follower marker signal for marker synchronizing, rising
edge
Follower marker (in-
verse)
Follower marker signal for marker synchronizing, falling
edge
Indicates the sign of speed reference after the ramp.
Controls the direction of slaves.
Homing is completed with the selected homing func-
tion.
Positioning: Target position reached.
Synchronization: Slave position aligned with master po-
sition.
Maximum position error exceeded.
A position limit is reached (parameter 3-06 Minimum Po-
sition or parameter 3-07 Maximum Position).
Target position is reached in touch probe position
mode.
Touch probe positioning active.
The touch sensor has been detected.