Instructions for use | Atlan A100 (XL), A300 (XL), A350 (XL) SW 2.1n 11
Safety-related information
Supply of an adequate anesthetic gas concentration to the patient:
When the anesthetic gas is measured by means of an integrated patient-gas
measurement module, an alarm will be generated if the anesthetic gas
concentrations are too high.
Monitoring of the airway pressure:
Alarms are issued depending on the set alarm limits.
Gas measurement
Breathing gas monitoring:
Inspiratory O
2 concentration FiO2
Inspiratory and expiratory measured values for O2, CO2, N2O, and
anesthetic gas as well as automatic anesthetic agent identification (only with
the patient-gas measurement module)
The gas composition is measured with ISO accuracy.
Monitoring of breathing gas concentrations:
Alarms will be issued depending on the set alarm limits or if the gas
measurement fails.
2.7 User group requirements
The term "user group" describes the personnel responsible who have been
assigned by the operating organization to perform a particular task on a product.
2.7.1 Duties of the operating organization
The operating organization must ensure the following:
Every user group has the required qualifications (e.g., has undergone specialist
training or acquired specialist knowledge through experience).
Every user group has been trained to perform the task.
Every user group has read and understood the relevant chapters in this
document.
2.7.2 User groups
Clinical users
This user group operates the product in accordance with the intended use.
Users have medical specialist knowledge in the field of anesthesia. Users have
knowledge of device monitoring and perioperative care.
Reprocessing personnel
This user group carries out the necessary activities to reprocess the product.
Reprocessing personnel has specialist knowledge in the reprocessing of medical
devices.
Service personnel
This user group installs the product and performs the service activities.
Service personnel has specialist knowledge in electrical and mechanical
engineering and experience in the servicing of medical devices.

Table of Contents

Other manuals for Dräger Atlan A100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Atlan A100 and is the answer not in the manual?

Dräger Atlan A100 Specifications

General IconGeneral
BrandDräger
ModelAtlan A100
CategoryMedical Equipment
LanguageEnglish

Related product manuals