9.3 Display view during ongoing operation (example)
Fig. 92: Operating indicator (example)
Pos. Designation
1
Pump name
Ä
Chapter 7.9.1 ‘Pump name’ on page 84
2
Maximum metering output in l/h (depending on the selected metering mode)
Ä
Chapter 9.7.1 ‘Metering mode’ on page 144
3
Metering mode (s, m, l, v)
Ä
Chapter 9.7.1 ‘Metering mode’ on page 144
4
Level display of the metering container
Ä
Chapter 9.5 ‘Changing a container - Empty signal’ on page 140
5
Maintenance display
Ä
Chapter 9.6 ‘Confirm the pump service’ on page 143
6
Display of the access code
/ and the elapsing timer for the short-term cancellation of an
access code.
7
Variable status displays (OGM, calibration, batch, external enable, access code, Bluetooth, etc.)
Ä
Chapter 9.3.1 ‘Symbols in operating mode’ on page 137
8
Current, day, date and time
Ä
Chapter 7.9.2 ‘Selecting the date/time’ on page 85
9 Test button for manual metering and to bleed the system
10
Menu button for calling up the settings
Ä
Chapter 7.6 ‘Main menu’ on page 66
11 Start button in standby position ("ON" operating mode)
12 Display of the current percentage metering capacity
13
Current metering capacity
Ä
Chapter 9.4 ‘Setting or changing the pump capacity in L’ on page 139
14
Current operating mode
Ä
Chapter 9.8.1 ‘Operating Mode’ on page 148
15
Metered chemical setting
Ä
Chapter 7.9.10 ‘Dosing chemical’ on page 98
The pump is operated via the Start button (pos. 11).
If the pump is in operation, the background of the [Metering mode] (pos. 3) flashes, and
the Start button changes to the Pause button .
Operation
136Rev. 2-05.2018