7.9.8.1 Acknowledge automatically:
The pump switches to Pause on empty signal and the empty signal symbol is displayed in
red . The suction pipe issues a "Full" signal to the pump after a container change and
the container change is detected and accepted without further confirmation.
Fig. 54: Acknowledge automatically
[Acknowledge automatically] - setting:
1.
[Main menu] :
Ä
Chapter 7.6 ‘Main menu’ on page 66
2.
[Configuration menu] :
Ä
Chapter 7.9 ‘Overview - Configuration’ on page 83
3. Use the scrollbar to scroll to the [Select empty signal]
menu option.
4. [Select empty signal] - select.
5. If required, ‘empty message contact’: ‘closed contact = select empty signal’
ð
After selecting this, a check mark is set in the selection field.
6.
[ Press the Next button] .
ð
Screen changes to the acknowledgement query of the ‘empty signal’.
7. [Acknowledge automatically] - select.
8.
Pressing the button saves the setting.
ð
The screen switches to the overview: [Configuration menu].
9.
Pressing the button returns to the [Main menu].
10.
Pressing the button returns to the [Operating display].
Control / software
95 Rev. 2-05.2018