9.7 Changeover ‘Metering mode’
9.7.1
Metering mode
Selecting a corresponding [Metering mode] (
/ / / ) makes it possible to extend the
suction duration per stroke (suction stroke duration) and thus adjust the metering to high
product viscosities or challenging suction conditions.
This extension of the suction stroke duration simultaneously results in a reduction in the
max. metering output (see tables below).
Type 00510x:
Metering
mode Display
Metering
output
100 %
(V)
Max. stroke
frequency
at 100%
(¦)
Stroke
volume
(V
h
)
Suction
stroke
Duration
(S
t
)
min. metering
stroke
duration
(P
t
)
Standard
5 l/h 155 / min
0,53 l/h
190 ms
197 ms
Medium 4,17 l/h 141 / min 228 ms
Low 3,33 l/h 111 / min 342 ms
Variable
2,5 - 5 l/h 104 - 155 / min 380 - 190 ms
Type 01110S:
Metering
mode Display
Metering
output
100 %
(V)
Max. stroke
frequency
at 100%
(¦)
Stroke
volume
(V
h
)
Suction
stroke
Duration
(S
t
)
min. metering
stroke
duration
(P
t
)
Standard 11,0 l/h 176 / min
1,1 l/h
170 ms
171 ms
Medium 9,66 l/h 160 / min 204 ms
Low
7.73 l/h 126 / min 306 ms
Variable 5.8 - 11.0 l/h 117 - 176 / min 340 - 170 ms
Operation
144Rev. 2-05.2018