11.1 General troubleshooting and fault rectification
NOTICE!
With some error messages the pump should always be sent to the customer
service department as it is only possible to access the level of the control to
which these messages relate.
The
Ä
‘Information about sending pumps to Customer Service.’ on page 171
should be observed!
Fault description Cause Remedy
Metering pump does not work.
No display on ‘EcoAdd’ unit.
Mains cable damaged. Change mains cable.
Incorrect voltage. Check mains voltage.
No suction on pump despite venting
and max. stroke.
Deposits, sticking valves,
drying out of valves.
Flush out the metering head
via the suction line; if
necessary also remove the
valves and clean or replace
them.
Metering head is leaking, medium
escapes through the diaphragm
rupture drain.
Metering head is loose. Tighten the metering head
fastening screws crosswise.
Tear in diaphragm. Replace diaphragm.
No metering despite full metering
container
.
Suction lance float is
blocked.
Make float functional.
Suction pipe connector or
link connector is loose or
not inserted.
Tighten connector, clean
contacts, check whether link
connector is inserted
Defective suction lance
cable.
Replace empty signal device.
Operational malfunctions / Troubleshooting
172Rev. 2-05.2018

Table of Contents

Other manuals for Ecolab EcoAdd

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecolab EcoAdd and is the answer not in the manual?

Ecolab EcoAdd Specifications

General IconGeneral
BrandEcolab
ModelEcoAdd
CategoryWater Pump
LanguageEnglish

Related product manuals