7 - Fault Finding
124
Hydraulic System, Y-version
FAULT PROBABLE CAUSE CONTROL/REMEDY
Boom slow/erratic. Air in the system. Loosen ram connection and activate hydraulics until
oil flow has no air in it (no bubbles or milky look).
Regulation valve incorrectly set. Open or close until desired speed is achieved (turning
clockwise = less speed).
Remember oil must be at operating temperature.
Insufficient hydraulic pressure. Check output pressure of tractor hydraulics. Minimum
for sprayer is 170 bar.
Insufficient amount of oil in tractor reservoir. Check and fill if needed.
Ram not functioning. Restrictor or regulation valve blocked. Secure boom. Dismantle and clean.
Hydraulic system fold/tilt functions will not operate. Power supply. Check for proper 12 V power supply.
One function (fold or tilt) will not operate. Various. Check for defective switches.
Check continuity of cables.
Check for operation of applicable solenoid (coil not
activating or plunger stuck).
Check for short circuit in wiring junction box at rear of
sprayer.
Dirt in the restrictor port of the cylinder.
Multiple hydraulic functions with one switch
activated.
Various. Check for correct solenoid electric/hydraulic hook-up.
Check for short circuit in wiring in the junction box at
rear of sprayer.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi MASTER plus HYS and is the answer not in the manual?

Hardi MASTER plus HYS Specifications

General IconGeneral
BrandHardi
ModelMASTER plus HYS
CategoryFarm Equipment
LanguageEnglish

Related product manuals