5 - Operation
90
Operating Limits
The following things are important when considering the performance of the sprayer.
Maximum driving speed
Pressure setting
Minimum / maximum volume rate
The operating limits for your sprayer are closely related to:
9. Pump size
10. Boom width
11. Nozzle size
In the table below, the operating limits for volume rate are calculated, when driving at different speeds.
÷
NOTE! The specified nozzle type is a standard flat fan nozzle. Other special nozzle types will show different results. Ask
your HARDI dealer if in doubt.
μ
ATTENTION! It is recommended not to drive faster than 16 km/h when spraying.
μ
ATTENTION! The pressure range for the nozzles are 1.5 - 5 bar (except for HARDI INJET nozzles, which are ranging from
3-8 bar). The spraying pressure should be within these limits.
μ
ATTENTION! In the table below, the specified combination of nozzle size and sprayer setup is not suitable, as the full
pressure range of 5 bar for the nozzle cannot be reached, when spraying the maximum volume rate (l/ha) on the crop.
This is due to the nozzle design.
÷
According to the standard for environmental requirements for sprayers, ISO 16119 / EC Directive 2009/127/EC
(amending 2006/42/EC), the farmer shall be able to use the full pressure range.
Nozzle size Min. volume rate (l/ha) Max. volume rate (l/ha)
HARDI ISO F-110 4 km/h 8 km/h 12 km/h 16 km/h 4 km/h 8 km/h 12 km/h 16 km/h
02 (yellow) 171 85 57 43 309 155 103 77
025 (purple) 213 106 71 53 387 194 129 97
03 (blue) 255 127 85 64 465 232 155 116
04 (red) 339 170 113 85 621 310 207 155
05 (brown) 423 212 141 106 774 387 258 194
06 (grey) 510 255 170 128 930 465 310 233
08 (white) 678 339 226 170 1239 620 413 310
10 (light blue) 849 424 283 212 1548 774 516 387
Pump model Boom width Nozzle size
364 16 m 10 (light blue)
364 18 m 10 (light blue)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi MASTER plus HYS and is the answer not in the manual?

Hardi MASTER plus HYS Specifications

General IconGeneral
BrandHardi
ModelMASTER plus HYS
CategoryFarm Equipment
LanguageEnglish

Related product manuals