10. Set linkage method. See Linkage Method
Sengs .
8.2.6 Set Unaended Baggage Detecon
Unaended baggage detecon is used to detect the objects le over in the predened area.
Linkage methods are triggered aer the object is le and stays in the area for a set me period.
Steps
1. Go to
Conguraon → Event → Smart Event → Unaended Baggage Detecon .
2. Check Enable.
3.
Oponal: Click Lock to lock PTZ control to prevent the interrupon from other PTZ related
acon during conguraon.
Normally, the PTZ control is automacally locked when you enter the conguraon interface.
You can manually resume the lock when the countdown is over.
4. Adjust the live image to the desired scene by using PTZ control
buons.
5. Draw detecon area.
1) Select a Region No.. Up to 4 regions can be set.
2) Click
Detecon Area.
3) Click on the live image to draw the boundaries of the detecon area, and right click to
complete drawing.
6. Set
detecon parameters.
Sensivity
The value of the sensivity denes the size of the object which can trigger the
alarm, when the sensivity is high, a very small object can trigger the alarm.
Threshold It stands for the me of the objects le in the area. Alarm is triggered aer the
object is le and stays in the area for the set me period.
Figure 8-9 Draw Area
7. Click Save.
8. Repeat above steps to set other regions.
Stched PanoVu Camera with PTZ User Manual