202 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
Configuration Signature is Zero
Description: ADU detected that NVRAM contains a configuration signature of
zero. Old versions of the server setup utility could cause this.
Action: Run the latest version of server setup utility to configure the controller
and NVRAM.
Configuration Signature Mismatch
Description: Array accelerator board is configured for a different array
controller board. Configuration signature on array accelerator board does not
match the one stored on the array controller board.
Action: To recognize the array accelerator board, run ACU ("Array
Configuration Utility" on page 115
).
Controller Communication Failure Occurred
Description: Controller communication failure occurred. ADU was unable to
successfully issue commands to the controller in this slot.
Action:
1. Be sure all cables are properly connected and working.
2. Be sure the controller is working, and replace if needed.
Controller Detected. NVRAM Configuration not Present
Description: EISA NVRAM does not contain a configuration for this controller.
Action: Run the server setup utility to configure the NVRAM.
Controller Firmware Needs Upgrading
Description: Controller firmware is below the latest recommended version.
Action: Run Options ROMPaq to upgrade the controller to the latest firmware
revision.