EasyManuals Logo
Home>HP>Server>ProLiant ML370 Generation 4

HP ProLiant ML370 Generation 4 User Manual

HP ProLiant ML370 Generation 4
317 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #272 background imageLoading...
Page #272 background image
272 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
•
Audible Beeps: None
•
−
•
Replace the failed drive and press the F1 key to rebuild the array. If the drive
rebuild is not successful or is aborted because the system rebooted before the
rebuild of the drive completed, another version of the 1786 POST error
message will be displayed. Refer to the following message.
1786-Slot 1 Drive Array Recovery Needed. Automatic Data Recovery
Previously Aborted!...
...The following SCSI drive(s) need Automatic Data Recovery: SCSI Port Y: SCSI ID Z
Select F1 to retry Automatic Data Recovery to drive. Select F2 to continue without starting
Automatic Data Recovery.
Possible Cause: System is in Interim Data Recovery Mode and a failed or
replacement drive has not yet been rebuilt. This message is displayed if the F2
key was pressed during a previous boot or if the F1 key was pressed during a
previous boot and the system rebooted before the rebuild of the drive completed.
Action:
Perform one of the suggested actions:
− Press the F1 key to retry Automatic Data Recovery to the drive. Data
will be automatically restored to drive X when a failed drive has been
replaced, or to the original drive if it is working again without errors.
Press the F2 key to continue without recovery of data to the drive. The
failed drive will not be rebuilt and the system will continue to operate in
a failed state of Interim Data Recovery Mode.
If drive recovery is not successful, run ADU ("Array Diagnostic Utility" on
page 126
) for more information.
− If the replacement drive failed, replace with another drive.
− If the rebuild was aborted due to a read error from another physical drive
in the array, back up all readable data on the array, run ADU, and then
restore the data.
1787-Drive Array Operating in Interim Recovery Mode...
...Physical drive replacement needed: Drive X

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML370 Generation 4 and is the answer not in the manual?

HP ProLiant ML370 Generation 4 Specifications

General IconGeneral
BrandHP
ModelProLiant ML370 Generation 4
CategoryServer
LanguageEnglish

Related product manuals