218 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
Storage Enclosure on SCSI Bus X Indicated that the Fan is Degraded...
...SOLUTION: this condition usually occurs on enclosures with multiple fans and one of
those fans has failed. Replace any fans not operating properly.
Description: One or more fans in the external storage unit have failed.
Action: Replace the failed fans.
Storage Enclosure on SCSI Bus X Indicated that the Fan Module is Unplugged...
...SOLUTION: Make sure the fan module is properly connected.
Description: A fan in the external storage unit is not connected properly.
Action: Check and reseat all fan connections securely.
Storage Enclosure on SCSI Bus X - Wide SCSI Transfer Failed...
...SOLUTION: This may indicate a bad SCSI cable on bus X. Try replacing the cable.
Description: A cable on bus X has failed.
Action:
1. Replace the failed cable.
2. If the problem persists, contact an authorized service provider.
Swapped Cables or Configuration Error Detected. A Configured Array of Drives...
...was moved from another controller that supported more drives than this controller
supports.
SOLUTION: Upgrade the firmware on this controller. If this doesn’t solve the problem,
then power down system and move the drives back to the original controller.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML370 Generation 4 and is the answer not in the manual?

HP ProLiant ML370 Generation 4 Specifications

General IconGeneral
BrandHP
ModelProLiant ML370 Generation 4
CategoryServer
LanguageEnglish

Related product manuals