Troubleshooting 241
203-Memory Address Error
Audible Beeps: None
126
Possible Cause: Memory failure detected.
Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page
) and
replace failed components as indicated.
207-Memory Configuration Warning - DIMM In Socket x does not
have Primary Width of 4 and only supports standard ECC
Advanced ECC does not function when mixing DIMMs with Primary Widths of x4 and x8.
Audible Beeps: 1 long, 1 short, or none
Possible Cause: Installed DIMMs have a primary width of x8.
Action: Install DIMMs that have a primary width of x4 if Advanced ECC
memory support is required.
207-Invalid Memory Configuration - DIMMs Must be Installed
Sequentially
Audible Beeps: 1 long, 1 short
Possible Cause: Installed DIMMs are not sequentially ordered.
Action: Reinstall DIMMs in proper order.
207-Invalid Memory Configuration - DIMM Size Parameters Not
Supported.
Audible Beeps: 1 long, 1 short
Possible Cause: Installed memory module is an unsupported size.
Action: Install a memory module of a supported size.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML370 Generation 4 and is the answer not in the manual?

HP ProLiant ML370 Generation 4 Specifications

General IconGeneral
BrandHP
ModelProLiant ML370 Generation 4
CategoryServer
LanguageEnglish

Related product manuals