Troubleshooting 217
Description: A power supply in the external storage unit has failed.
Action: Replace the power supply.
Storage Enclosure on SCSI Bus X Indicated an Overheated Condition...
...SOLUTION: Make sure all cooling fans are operating properly. Also be sure the
operating environment of storage enclosure is within temperature specifications.
Description: The external storage unit is generating a temperature alert.
Action:
1. Be sure all fans are connected and operating properly.
2. Be sure the operating environment of the storage unit is within specifications.
3. For better airflow, remove any dust buildup from fans or other areas.
4. Check the server documentation for allowable temperature specifications and
additional tips.
5. If the problem persists, replace the fan.
Storage Enclosure on SCSI Bus X is Unsupported with its Current Firmware
Version...
...SOLUTION: Upgrade the firmware version on the storage enclosure.
Description: The firmware version of the external storage unit is not supported.
Action: Upgrade the firmware.
Storage Enclosure on SCSI Bus X Indicated that the Fan Failed...
...SOLUTION: Replace the fan.
Description: The cooling fan located in the external storage unit has failed.
Action: Replace the fan.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML370 Generation 4 and is the answer not in the manual?

HP ProLiant ML370 Generation 4 Specifications

General IconGeneral
BrandHP
ModelProLiant ML370 Generation 4
CategoryServer
LanguageEnglish

Related product manuals