Troubleshooting 269
1778-Drive Array Resuming Automatic Data Recovery Process
•
• When powering down the system, the server must be powered down before
powering down any external storage systems.
Audible Beeps: None
Possible Cause: A controller reset or power cycle occurred while Automatic
Data Recovery was in progress.
Action: No action is required.
1779-Slot X Drive Array - Replacement drive(s) detected OR
previously failed drive(s) now operational:...
...Port Y: SCSI ID Z:
Restore data from backup if replacement drive X has been installed.
Audible Beeps: None
Possible Cause: More drives failed (or were replaced) than the fault-tolerance
level allows. Unable to rebuild array. If drives have not been replaced, this
message indicates an intermittent drive failure.
Action: Be sure the system is always powered up and down correctly:
When powering up the system, all external storage systems must be powered
up before (or at the same time as) the server.
1783-Slot X Drive Array Controller Failure
Audible Beeps: None
Possible Cause: Controller failed. If this message is displayed after Options
ROMPaq is run, problems may have occurred while attempting to flash the
ROM.
Action:
1. Reseat the array accelerator module.
2. Reseat the controller in the PCI slot.