Troubleshooting 263
1753-Slot z Drive Array - Array Controller Maximum Operating
Temperature Exceeded During Previous Power Up
Audible Beeps: None
Possible Cause: Controller is overheating.
Action: Replace the module.
1. Reseat array accelerator module.
Action: Be sure adequate system cooling and sufficient airflow across controller
are available.
1754-Slot x Drive Array - RAID ADG configured but ADG is not
supported on this controller model.
Audible Beeps: None
Possible Cause: RAID ADG configured by ADG is not supported on this
controller model.
1762-Slot x Drive Array - Controller Firmware Upgrade Needed
Audible Beeps: None
Possible Cause: Different firmware versions are running on the base controller
and the expansion module controller.
Action: Upgrade the firmware on both the SA6400 base controller and SA6400
expansion module controller to the same version.
1763-Array Accelerator Daughtercard is Detached; Please Reattach
Audible Beeps: None
Possible Cause: Array accelerator module is loose, missing, or defective.
Action:
2. If the problem persists, replace the array accelerator module.