Troubleshooting 267
Audible Beeps: None
Possible Cause: External and internal connectors of the specified SCSI ports are
connected to drives. The indicated SCSI bus is disabled until this problem is
resolved.
Action: The SCSI bus is not properly terminated when internal and external
drives are connected concurrently to the same SCSI bus.
1. 27Power down the server ("Powering down the server" on page
).
2. Be sure the cables to the specified port are connected properly and securely
("Loose connections" on page 154
).
3. Reconfigure the drives to different SCSI ports.
1776-Drive Array Reports Improper SCSI Port 1 Cabling
Audible Beeps: None
•
•
•
•
•
Possible Cause:
The integrated array enabler board failed.
The integrated Smart Array option ROM is corrupted.
The I/O board, media backplane fan board, or media backplane failed.
Action:
Replace the integrated array enabler board.
Replace the integrated Smart Array option ROM.
CAUTION: Only authorized technicians trained by HP should
attempt to remove the I/O board. If you believe the I/O board requires
replacement, contact HP Technical Support before proceeding.
• Rebooting after installing each item, replace in the following order: media
backplane fan board, media backplane, and I/O board.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML370 Generation 4 and is the answer not in the manual?

HP ProLiant ML370 Generation 4 Specifications

General IconGeneral
BrandHP
ModelProLiant ML370 Generation 4
CategoryServer
LanguageEnglish

Related product manuals