Troubleshooting 259
Audible Beeps: None
Possible Cause: Flash ROM is failing. The controller detected a checksum
failure but is unable to reprogram the backup ROM.
Action:
1. Upgrade the firmware using Options ROMPaq.
2. If the problem persists, replace the controller.
1714-Slot z Drive Array Controller - Redundant ROM Checksum
Error...
...Backup ROM has automatically been activated. Check firmware version.
Audible Beeps: None
Possible Cause: The controller flash operation interrupted by power-cycle, or
flash ROM is failing. The controller has detected a ROM checksum error and
automatically switched to the backup ROM image.
Action: If this backup ROM image is a lower version than the originally running
image, upgrade controller firmware using Options ROMPaq.
1715-Slot x Drive Array Controller - Memory Error(s) Occurred
...Warning: Corrected Memory Error(s) were detected during controller memory self-test...
Audible Beeps: None
Possible Cause: The memory is beginning to fail.
Action: If this error persists, replace the controller.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML370 Generation 4 and is the answer not in the manual?

HP ProLiant ML370 Generation 4 Specifications

General IconGeneral
BrandHP
ModelProLiant ML370 Generation 4
CategoryServer
LanguageEnglish

Related product manuals