Pass-Through command issued by management
application (such as GUI) failed due to invalid
data length.
ErrorApp
QLBI_Passthru: Invalid
data length %d bytes
41701
Pass-Through command issued by management
application (such as GUI) was interrupted or
timed out.
ErrorApp
QLBI_Passthru: Invalid
data length %d bytes
41717
IOCTL operation unsupported. Operation code
provided in log message.
ErrorApp
QLBI_Ioctl: ERROR: Opera-
tion (0x%x) not supported
in this mode
41750
Report LUNs command failed. The Report LUNs
command was issued by the router as part of
its discovery process.
ErrorApp
QLBI_GetLunList: REPORT
LUNS command failed
41768
Report LUNs command failed with check con-
dition status. The Report LUNs command was
issued by the router as part of its discovery
process.
ErrorApp
QLBI_GetLunList: REPORT
LUNS command failed with
CHECK CONDITION, SCSI
STATUS 0x%02X
41769
Failed to allocate LUN object; out of resources.ErrorApp
QLBI_GetLunList: Lun al-
location failed for LunId
%d
41771
Login attempted using FC virtual port (VP) in-
dex that is out-of-range (range = 031). Index
reported in log message.
ErrorApp
QLFC_Login: VpIndex (%d)
out of range
41994
Login attempted using FC VP index that has
not been configured. Operation attempted on
an unconfigured VP.
ErrorApp
QLFC_Login: VP Index 0x%x
not configured
41995
Attempting login but FC connection cannot be
opened.
ErrorApp
QLFC_Login: Can't open
connection
42002
Attempting logout of device for which there is
no active path (WWPN not found).
ErrorApp
QLFC_Logout: No active
path to device. WWPN:
%.2X%.2X%.2X%.2X%.2X%.2X%.2X%.2X
42024
Logout attempted using FC VP index that has
not been configured. Operation attempted on
an unconfigured VP.
ErrorApp
QLFC_Logout: VP Index
0x%x not configured
42027
Event notification; FC processor encountered
a system error (unrecoverable firmware error).
ErrorApp
QLFC_HandleTeb: System
Error
42068
Event notification; FC driver encountered a
fatal error.
ErrorApp
QLFC_HandleTeb: Driver
Fatal Error
42069
Event notification; FC port logged out.ErrorApp
QLFC_HandleTeb: Driver
Fatal Error
42072
Failed to allocate object for iSCSI session; out
of session resources.
ErrorApp
QLIS_AllocateSessionOb-
ject: Out of session re-
sources
42242
Received iSCSI PDU with duplicate command
sequence number (CmdSN). Command PDU
will be dropped.
ErrorApp
QLIS_EnqueueiScsiPdu: Du-
plicate PDU, CmdSN %d
(0x%x), dropping it
42252
Log messageslog messages212

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 6100 - Enterprise Virtual Array and is the answer not in the manual?

HP StorageWorks 6100 - Enterprise Virtual Array Specifications

General IconGeneral
BrandHP
ModelStorageWorks 6100 - Enterprise Virtual Array
CategoryStorage
LanguageEnglish

Related product manuals