AquaLink
®
Touch™ Owner's Manual
14.2.5 ORP Alarm - High Alert
The high alert alarm sets an alarm to deactivate the
controller in the event of an ORP reading that is out of
high range. This could be an indication of a mechanical
malfunction in the feeding system.
From the CHEMLINK ORP setup screen, highlight the
HI ALERT values. Use the UP and DOWN arrows to
adjust the high alert values. Touch SAVE when finished.
ChemLink
H
ome Menu OneTouch Help Back Status
Photos
Power
Thu January 1, 2009 3:03 PM
ChemLink 1 ORP Status
Feeder LIQUID
Feed TM 15 SEC
Delay OT 45 Min
Set Point 7.0
High Alert 8.0
Adjust
Low Alert 6.0
Page
Down
Page
Up
Save
Orp
pH
Default 950
Range 350 to 950
14.2.6 ORP Alarm - Low Alert
The low alert alarm sets an alarm to deactivate the
controller in the event of an ORP reading that is out of
low range. This could be an indication of a mechanical
malfunction in the feeding system.
From the CHEMLINK ORP setup screen, highlight the
LOW ALERT values. Use the UP and DOWN arrows to
adjust the low alert values. Touch SAVE when finished.
ChemLink
H
o
m
e
Menu OneTouch Help Back Status
Photos
Power
Thu January 1, 2009 3:03 PM
ChemLink 1 ORP Status
Feeder LIQUID
Feed TM 15 SEC
Delay OT 45 Min
Set Point 7.0
High Alert 8.0
Adjust
Low Alert 6.0
Page
Down
Page
Up
Save
Orp
pH
Default 100
Range 100 to 650
14.2.7 Wait or Stop pH
From the CHEMLINK ORP setup screen, highlight
the WAIT PH/STOP PH entry. Use the UP and DOWN
arrows to adjust the wait/stop pH entry. Touch SAVE
when finished.
ChemLink
H
o
m
e
Menu OneTouch Help Back Status
Photos
Power
Thu January 1, 2009 3:03 PM
ChemLink 1 ORP Status
Wait pH NO
Stop pH YES
Next Clean Dec 22
Adjust
Page
Down
Page
Up
Save
Orp
pH
Wait for pH:
YES= ORP will not feed at the same time as pH.
NO= ORP will feed regardless of when pH feeds.
Default= YES
Stop for pH:
YES= ORP will not feed if the pH is out of range.
NO= ORP will feed regardless of pH.
Default= YES

Table of Contents

Other manuals for Jandy AquaLink Touch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy AquaLink Touch and is the answer not in the manual?

Jandy AquaLink Touch Specifications

General IconGeneral
BrandJandy
ModelAquaLink Touch
CategoryController
LanguageEnglish

Related product manuals