AquaLink
®
Touch™ Owner's Manual
15.3 Controller Messages
CLEANER CANNOT BE TURNED ON WHILE SPA IS ON
This message is displayed if the pool cleaner is activated
when in spa mode (i.e., water is circulating to spa). The pool
cleaner requires that water be circulating to the pool in order
for it to operate. Return to pool mode to activate the cleaner.
CLEANER CANNOT BE TURNED ON WHILE SPILLOVER IS ON-
The return valve has been rotated to the spa position to give
the spa spillover effect.
FREEZE PROTECT
This message indicates that freezing conditions have been
detected by the freeze protection sensor, and that equipment
assigned to freeze protection (e.g., lter pump) are active.
See Section 10.11,
"Freeze Protection".
NOTE If a freeze protected Auxiliary is turned off
during freeze protection, a message will be
displayed indicating that item is off but will turn
on in X amount of minutes. The minutes will
vary depending on how long freeze mode has
been active from 1 to 15 minutes.
SENSOR OPEN
This error message indicates that the sensor is not installed
properly or is malfunctioning. Call your pool service person
to resolve this problem.
NOTE If the message reads WATER TEMP OPEN, the
heater will not fire. If message AIR TEMP OPEN
is displayed, freeze protection will not operate
correctly.
POOL HEATER ENABLED
This message indicates that the pool heater is ready to use
but is not actually ring. The lter pump must be on, and the
water temperature must be below the setting for the heater to
re.
PUMP WILL REMAIN ON WHILE SPILLOVER IS ON
This message is displayed when you attempt to turn off the
lter pump while a spa spillover is on. Since the lter pump
is necessary for spillover operation, the pump will remain on
until the spillover is turned off.
PUMP WILL TURN OFF AFTER COOL DOWN CYCLE
This message indicates that the lter pump is circulating
water to cool down the heater. The lter pump will continue
to run for ve (5) minutes to protect the heater from damage,
whenever the heater has red and has been off for less than
ve (5) minutes.
PUMP WILL TURN ON AFTER DELAY
This message is displayed during pool/spa switching. The
AquaLink RS waits 35 seconds while the valves turn from
pool position to spa position (or vice-versa) before activating
the lter pump.
SERVICE MODE
This message indicates that the Controller has been locked
out from the power center and is not operational. Service
mode is used by the pool service person to aid them in
servicing the pool. The Controller will not be functional
until the switch at the Power Center is moved back to AUTO
mode.
SENSOR SHORT
This error message indicates that the sensor is not installed
properly or is malfunctioning. Call your pool service person
to resolve this problem.
NOTE If the message reads WATER TEMP SHORT,
the heater will not fire. If the message AIR
TEMP SHORT is displayed, freeze protection
will not operate correctly.
SPA WILL TURN OFF AFTER COOL DOWN CYCLE
When the system is in Spa Mode (water is circulating to the
spa) and the Spa button is pressed to switch water circulation
to the pool, the system will not switch to Pool Mode for
ve (5) minutes, and will continue to circulate the water [if
the heater has red and has been off for less than ve (5)
minutes]. This delay allows water to cool the heater down by
circulating water through it, preventing equipment damage.
TIMED AUX ON, WILL TURN OFF AFTER 30 MINUTES
This message indicates that a timed auxiliary (usually a
blower) has been activated and will turn off after 30 minutes.
Some labels (e.g., blower, ll line) have a built-in 30 minute
shut off.
TIMEOUT MODE
This message indicates that the Controller has been locked
out from the Power Center and is not operational. TIME
OUT mode is used by the pool service person to aid them in
servicing the pool. The Controller will not be functional for
three hours, or until the switch at the Power Center is turned
back to AUTO mode.
SPILLOVER DISABLED WHILE SPA IS ON
This message is displayed when the spa spillover is pressed
while in spa mode (water circulation is to spa). The spillover
requires that water circulation is to pool in order to operate.
The spillover will activate when the system switches back to
pool mode.

Table of Contents

Other manuals for Jandy AquaLink Touch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy AquaLink Touch and is the answer not in the manual?

Jandy AquaLink Touch Specifications

General IconGeneral
BrandJandy
ModelAquaLink Touch
CategoryController
LanguageEnglish

Related product manuals