Section 2: Getting started Model 6517B Electrometer Reference Manual
2-2 6517B-901-01 Rev. C / August 2015
1 ANNUNCIATORS
ï‚§ EDIT: Editing voltage source values
ï‚§ ERR: Questionable reading
ï‚§ REM: In remote
ï‚§ TALK: Addressed to talk
ï‚§ LSTN: Addressed to listen
ï‚§ SRQ: Service Request
ï‚§ REL: Relative reading displayed
ï‚§ FILT: Digital filter enabled
ï‚§ MATH: Math calculation enabled
ï‚§ AUTO: Autoranging enabled
ï‚§ ARM: Trigger armed; not in idle
ï‚§ *(asterisk): Reading being stored
2 FUNCTION KEYS
Select measurement function; volts (V), amps (I), resistivity (R) or coulombs (Q).
3 RANGE KEYS
ï‚§ Up arrow: Moves to higher range; increments digit.
ï‚§ Down arrow: Moves to lower range; decrements digit.
ï‚§ AUTO: Enables/disables autorange.
4 HANDLE
ï‚§ Pull out and rotate to desired position.
5 DISPLAY KEYS
ï‚§ PREV/NEXT: Scroll through multiple displays of a function.
6 OPERATION KEYS
ï‚§ Z-CHK: Enables/disables zero check; enable zero check before changing functions.
ï‚§ REL: Enables/disables relative reading.
ï‚§ FILTER: Displays digital filter status for present function and toggles filter on/off.
ï‚§ MATH: Displays math calculation and toggles math on/off if configured.
ï‚§ TRIG: Triggers unit.
ï‚§ SEQ: Performs selected test sequence.
ï‚§ Left arrow and right arrow: Move cursor among data entry digits, menu selections, and
information displays.
ï‚§ INFO: Shows context-sensitive information about the present display.
ï‚§ LOCAL: Cancels remote operation.
ï‚§ STORE: Enables data storage.
ï‚§ RECALL: Displays reading data (reading, number, time); use PREV/NEXT DISPLAY for
maximum, minimum average, standard deviation.
ï‚§ CONFIG: Configures functions and operations.
ï‚§ MENU: Saves/restores instrument conditions; sets up communications; performs calibration
and self-tests; defines limits, digital output, and other miscellaneous operations.
ï‚§ EXIT: Cancels selection, moves back within menu structure.
ï‚§ ENTER: Holds reading, enters selection, moves down within menu structure.
7 VOLTAGE SOURCE KEYS
ï‚§ OPER: Toggles V-source between operate and standby.
ï‚§ Increase and decrease keys: Adjusts V-source value.

Table of Contents

Other manuals for Keithley 6517B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 6517B and is the answer not in the manual?

Keithley 6517B Specifications

General IconGeneral
BrandKeithley
Model6517B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals